MDG-50
Installation Manual
For replacement parts, contact the distributor from which the dryer
was purchased or contact:
Maytag Co.
403 West Fourth St North
Newton, Iowa 50208
(515) 787-7000
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez.
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
122298SL/cj Part No. 113067
Vedere la pagina 0
1 2 3 4 5 6 ... 54 55

Sommario

Pagina 1 - Installation Manual

MDG-50Installation ManualFor replacement parts, contact the distributor from which the dryerwas purchased or contact:Maytag Co.403 West Fourth St Nort

Pagina 2 - Important

6SECTION IISPECIFICATIONSA. SPECIFICATIONS* 50 lbs reversing dryer available with 3-phase (3ø) motors standard with 1/2 HP motors.** Size of piping t

Pagina 3 - FOR YOUR SAFETY

7NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice orobligation.SpecificationsMDG-50

Pagina 4

8SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Pagina 5 - Table of Contents

9B. LOCATION REQUIREMENTSBefore installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of suchcodes or or

Pagina 6

10C. DRYER ENCLOSURE REQUIREMENTSBulkheads and partitions should be made of noncombustible materials and must be located a minimum of12-inches above

Pagina 7 - SECTION I

11D. FRESH AIR SUPPLY REQUIREMENTSThe MDG-50 air supply (make-up air) must be given careful consideration to assure proper performance ofeach dryer.

Pagina 8 - B. SAFETY PRECAUTIONS

12E. EXHAUST REQUIREMENTSExhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork willcreate excessi

Pagina 9

13SINGLE DRYER VENTINGIMPORTANT: For exhaust duct runs over 30 feet a minimum size of 10 inches must be used.HORIZONTAL VENTINGWhen horizontal single

Pagina 10 - SECTION II

14If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross sectionarea of the ductwork must be incre

Pagina 11 - Specifications

15MULTIPLE DRYER (COMMON) VENTINGIf it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeledi

Pagina 12 - SECTION III

Retain This Manual In A Safe Place For Future ReferenceDATE OF PURCHASE MODEL NO.DISTRIBUTORS NAMESerial Number(s)MDG-50“IMPORTANT NOTE TO PURCHASER”I

Pagina 13 - B. LOCATION REQUIREMENTS

16MAN4218HORIZONTAL VENTINGILLUS. CVERTICAL VENTINGILLUS. D.MAN4230

Pagina 14

17IMPORTANT VENTING REMINDERS1. Ductwork size and installation should be done by a qualified professional.2. The dryer must be exhausted to the outdoo

Pagina 15

18F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and com

Pagina 16 - E. EXHAUST REQUIREMENTS

19NOTE: Component failure due to improper voltage application will VOID THE WARRANTY.3. GroundingA ground (earth) connection must be provided and inst

Pagina 17 - SINGLE DRYER VENTING

20If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cordor pigtail (wire size must conform to rating of

Pagina 18 - ILLUS. B

21a. 3-Phase (3ø) Wiring Connections/HookupFor gas dryers manufactured for operation at 3-phase (3ø),the electrical connections are made at the power

Pagina 19

22IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models, contactthe factory.IMPORTANT: The dryer must be connected to the

Pagina 20 - ILLUS. D

23G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing instal

Pagina 21 - IMPORTANT VENTING REMINDERS

242. Technical Gas Dataa. Gas Specifications* Measured at outlet sie of gas valve pressure tap when gas valve is on.b. Gas ConnectionsInlet connection

Pagina 22 - F. ELECTRICAL INFORMATION

253. Piping ConnectionsALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION, or in Canada, CAN/CGA

Pagina 23 - MUST BE PROVIDED

IMPORTANTYOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GASSUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THEMACHINE TO ALLOW ACCESS

Pagina 24

26Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch pipe gasloop be installed in the supply line servici

Pagina 25

27H. PREPARATION FOR OPERATION AND START-UPThe following items should be checked before attempting to operate the dryer:1. Read ALL "CAUTION,&qu

Pagina 26 - MDG-50 (GAS)

28I. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be performe

Pagina 27 - G. GAS INFORMATION

295. Make a complete operational check of ALL operating controls.NOTE: If computer program changes are required, refer to the computer programming sec

Pagina 28 - TYPE OF GAS

30NOTES: 1. If the anti-wrinkle program is active, the light emitting diode (L.E.D.) display will continueto read "donE," and the microproce

Pagina 29

31b. Select TemperatureThe dryer will start, the light emitting diode (L.E.D.) display will read the temperature cycle selected,and the drying time po

Pagina 30

322) Press the "E" on the keyboard (touch pad).3) The light emitting diode (L.E.D.) display will quickly show "Ld30," "LC04,&

Pagina 31

33SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Pagina 32 - I. PREOPERATIONAL TESTS

34SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARDS1. Before any dryer leaves the manufacturer, a warranty card is affixed to the glass of the

Pagina 33 - COIN MODELS

35SECTION VIROUTINE MAINTENANCEA. CLEANINGA program or schedule should be established for periodic inspection, cleaning, and removal of lint from var

Pagina 34

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY OR FIRE COULD RESULT.IMPOR

Pagina 35 - OPL MODELS

3690 DAYSInspect and remove lint accumulation in customer furnished exhaust ductwork system from dryer's internalexhaust ducting.WARNING: THE ACC

Pagina 36 - K. SHUT DOWN INSTRUCTIONS

37SECTION VIITROUBLESHOOTINGIMPORTANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLYAND THE GAS SUPPLY BEFORE ANY COVERS OR GUARDS AREREMOVED FR

Pagina 37 - SECTION IV

384. Failed microprocessor controller (computer).C. Drive motor (reversing) operates in one (1) direction only, stops and restarts in same direction..

Pagina 38 - SECTION V

393. Failed arc suppressor (A.S.) board (for Reversing Models ONLY).4. Failed microprocessor controller (computer).5. Failed 24 VAC transformer.H. Bot

Pagina 39 - SECTION VI

40M. Microprocessor controller (computer) locks up and light emitting diode (L.E.D.) display readserroneous messages or only partial segments...1. Tra

Pagina 40 - C. LUBRICATION

414. Failed ignitor and flame-probe assembly.5. Failed DSI module.6. Failed gas valve.Q. Dryer operates but is taking too long to dry...1. Exhaust duc

Pagina 41 - SECTION VII

423. Loose basket (tumbler) tie rod.4. Failed basket (tumbler) support.T. Excessive noise or vibration...1. Dryer is not leveled properly.2. Impellor

Pagina 42

43B. Drive motor (only) is not operating...1. Failed drive motor contactor.2. Failed reversing timer (for Reversing Models ONLY).3. Failed drive motor

Pagina 43

44H. Dryer operates but is taking too long to dry load...1. Heating unit cycling on hi-limit thermostat.2. Housekeeping...a. Lint screen and lint comp

Pagina 44

45When contacting Maytag Company certain information is required to insure proper service or parts informationfrom manufacturer. This information is

Pagina 45

Table of ContentsSECTION IIMPORTANT INFORMATION...3A. Receiving and Handling ..

Pagina 46 - DUAL TIMER MODELS

46THE DATA LABEL1. MODEL NUMBERThe model number is an Maytag Company number, which describes the size of thedryer and the type of heat (gas, electric,

Pagina 47

47SECTION IXREVERSING TIMER SPIN/DWELL ADJUSTMENTSDual timer models with "reversing option" have an electric reversing timer in the electric

Pagina 48

48SECTION XPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. Microprocessor Controller (Computer) Boarda. Upon completing installation of the

Pagina 49 - SECTION VIII

49e. Open main door. The dryer must stop and ALL output indicator lights on the back side of themicroprocessor controller (computer) board must go o

Pagina 50

503. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 882627a. Upon completing installation of thereplacement DSI m

Pagina 51 - SECTION IX

Part No. 113067 1- 01/12/99-150 2- 03/26/99-150 3- 12/15/99-1504- 01/19/00-150 5- 03/03/00-150 6* 10/30/00-1507- 03/27/01-200 8* 09/14/01-200

Pagina 52 - SECTION X

SECTION VIROUTINE MAINTENANCE ...35A. Cleaning ...

Pagina 53

3SECTION IIMPORTANT INFORMATIONA. RECEIVING AND HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners and

Pagina 54

4B. SAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize the risk offire or explosion or to preven

Pagina 55

5WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create afire hazard.WARNING: DO NOT use heat for drying articles that